Very Early Smoke Detection Apparatus
Very Early Smoke Detection Apparatus

Very Early Smoke Detection Apparatus

MOQ : 1 Piece

Very Early Smoke Detection Apparatus Specification

  • Fire Extinguisher Type
  • Not applicable (detection apparatus)
  • Voltage
  • 24V DC
  • Coating Type
  • Powder coated metal chassis
  • Mounting Type
  • Surface mounting
  • Operating Pressure
  • Ambient atmospheric
  • Energy Efficiency Rating
  • Low power consumption (typical 24V DC operation)
  • Connectivity Type
  • Ethernet, RS-485, Relay Output, Networked
  • Technology
  • Aspirating Smoke Detection (Laser-based detection chamber)
  • Features
  • Very early warning detection, High sensitivity, Networkable, Remote monitoring, Event logging
  • Coverage Area
  • Up to 2000 sqm (model dependent)
  • Shape
  • Rectangular housing
  • Installation Type
  • Wall-mounted or Rack-mounted
  • Working Temperature
  • -10C to +55C
  • Fire Class
  • A, B, C (depending on connected suppression systems)
  • Control Type
  • Microprocessor-based smart control panel
  • Application
  • Very Early Smoke Detection in critical areas, Server Rooms, Data Centers, Clean Rooms, Telecom, Industrial Applications
  • Max Flow Rate
  • Up to 120 l/min (based on sampling pipe design)
  • Capacity
  • Multiple pipe inlets (typically up to 4)
  • Diameter
  • Standard sensor pipe diameter: 25 mm
  • Pressure
  • Atmospheric, with internal aspirator fan
  • Filter Type
  • High-efficiency dust filter
  • Maintenance
  • Tool-less filter replacement, self-diagnostics
  • Response Time
  • Seconds to minutes depending on air flow and sensitivity
  • Sampling Points
  • Up to 100 sampling holes
  • Event Storage
  • Up to 18,000 events logged
  • Display
  • LCD status indicator with LED alarms
  • Humidity Range
  • 10% to 95% RH (non-condensing)
  • Alarm Levels
  • Multiple adjustable thresholds (Pre-Alarm, Fire 1, Fire 2)
  • Sounder Output
  • Integrated piezo sounder and remote output
 

Very Early Smoke Detection Apparatus Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash Against Delivery (CAD), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Delivery Time
  • 3-7 Days
 

About Very Early Smoke Detection Apparatus

Very Early Smoke Detection Apparatus

With an objective to serve clients in the best possible manner, we offer a broad gamut of Very Early Smoke Detection Apparatus. To minimize the possibility of damages, customers extensively install this apparatus at factories, restaurants, homes, hospitals and educational institutes to generate an escape alarm. It is manufactured using optimum quality components and pioneering techniques by dexterous professionals. The offered Very Early Smoke Detection Apparatus is available from us at cost effective rates within committed time frame.

Key points:

  • Simple installation
  • High sensitivity
  • Smooth functionality
  • Longevity

Product details

Area Coverage

2,000 m2

Pipe Length

200

Total Number of Alarm

4

Brand

Vesda

Ip Rating

IP30

Frequency

50 Hz

Automation Grade

Automatic

Usage/Application

Office Buildings

Material

Mild Steel



Intelligent Smoke Detection for Mission-Critical Environments

This apparatus leverages laser-based aspirating technology for highly sensitive and early detection of smoke. With adjustable alarm levels, extensive event storage, and a high-efficiency dust filter, it ensures timely response in areas where downtime is costly and safety is paramount. Its robust design supports flexible surface or rack mounting, remote monitoring, and easy filter replacement.


Easy Maintenance and Flexible Installation

Designed for both convenience and reliability, the unit offers tool-less filter replacement, self-diagnostics, and supports up to four pipe inlets. Its powder coated metal chassis assures durability, while networkable features make monitoring and event logging seamless across large facilities. The apparatus is suitable for diverse settings requiring low power consumption and variable mounting options.

FAQs of Very Early Smoke Detection Apparatus:


Q: How does the Very Early Smoke Detection Apparatus provide early warning?

A: The device uses advanced laser-based aspirating technology to continually sample air from up to 100 points. Adjustable thresholds allow for multiple alarm levelsPre-Alarm, Fire 1, and Fire 2enabling intervention well before smoke becomes visible, thus minimizing potential damage in sensitive environments.

Q: What is the process for maintaining the smoke detection system?

A: Maintenance is straightforward thanks to a tool-less filter replacement design. The apparatus performs self-diagnostics to monitor its own health, alerting operators via its LCD and LED indicators when attention is needed. Regular filter changes and event log reviews help ensure optimal performance.

Q: Where is this smoke detection solution typically installed?

A: It is ideal for server rooms, data centers, clean rooms, telecom facilities, and industrial applicationsanywhere early smoke detection is crucial. Its flexible mounting options (wall or rack) and coverage area (up to 2000 sqm) accommodate a range of critical infrastructure environments.

Q: What benefits does network connectivity provide for this apparatus?

A: With Ethernet and RS-485 connections, the unit can be integrated into building management systems for remote monitoring, event logging, and control. This ensures rapid response, easy scalability, and centralized management across large or distributed facilities.

Q: When should alarms be acted upon within the multiple adjustable thresholds?

A: Operators should investigate immediately upon receiving a Pre-Alarm or Fire 1 alert. Fire 2 threshold indicates an advanced smoke condition requiring urgent response. Adjustable thresholds allow tuning based on environmental sensitivity and operational needs.

Q: What applications are best served by this smoke detection technology?

A: Very Early Smoke Detection apparatuses excel in environments where asset protection and operational continuity are critical, such as data centers, server rooms, clean manufacturing spaces, and telecom or industrial settings, due to their rapid response and high accuracy.

Q: How does the event logging feature support firefighting and maintenance?

A: By storing up to 18,000 events, the system allows operators to analyze alarm history, refine response protocols, and conduct preventive maintenance, thereby improving long-term reliability and safety strategy.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Alarm System Category

Aspirating Smoke Detection System

Aspirating Smoke Detection System

Price 70000 INR / Piece

Minimum Order Quantity : 1 Piece

Features : Early Warning, High Sensitivity, Continuous Air Sampling, Fault Monitoring

Application : Industrial

Control Type : MicroprocessorBased

Working Temperature : 10C to +55C

Fire Suspension Systems

Fire Suspension Systems

Price 200001 INR / Set

Minimum Order Quantity : 1 Set

Features : Corrosion Resistant, Easy Operation, Quick Activation

Application : Industrial

Control Type : Automatic

Working Temperature : 30C to 55C

Red Fire Alarm

Red Fire Alarm

Price 700 INR / Piece

Minimum Order Quantity : 1 Piece

Features : Audible Siren, LED Indicator

Application : Industrial

Control Type : Manual

Working Temperature : 10C to 55C

Addressable Fire Alarm System

Addressable Fire Alarm System

Price 3,50,000 INR

Minimum Order Quantity : 1 Piece

Features : Realtime event monitoring, Early detection, System integration, Fault alarms, LCD display, Addressable devices support

Application : Commercial, Industrial and Residential buildings

Control Type : Automatic

Working Temperature : 10C to 50C



"We are providing our services and products in Vadodara, Gujarat region only"
Back to top